Catalogue images illustrate reference configurations. Please confirm BRONRY availability, final appearance, materials and performance specifications for your project.
1.0 mm PE high-barrier foil vent liner
Foam and foil liner formats for vented packaging closures.
Application-led selection
Closure integration; confirm liner diameter, thickness, sealing process and cap interface.
A closer look at the specification.
Reference catalogue values for this configuration. Confirm the final BRONRY specification and test report before use.
View reference source ↗| Airflow | 500-3000 mL/min/cm2 |
|---|---|
| Ingress protection | IP67–IP68; 2 m immersion for 1 hour stated in reference |
| Membrane material | Expanded PTFE (ePTFE) |
| Membrane properties | Water protection, Dust protection, Breathable, Oil resistance |
| Sealing method | Induction sealing |
| Construction | ePTFE / sealing film + aluminum foil + wax + paperboard |
| Liner material | PE |
An airflow value without a stated pressure differential cannot be directly compared with another test. Component IP information does not establish the rating of your finished enclosure.
Check the interface before integration.
Reference illustrations may contain Chinese annotations. They are for format comparison; use the approved drawing for production and tooling.
Good integration starts with the interface.
- Check the cap interface, liner size and sealing land before installation.
- Match the sealing process to the liner construction: compression or induction where applicable.
- Keep the sealing area clean and avoid blocking the gas path.
- Validate the filled package for liquid compatibility, leakage and pressure balancing.
Questions before you specify?
How do I choose a vent?+
Start with the mounting interface, enclosure volume, temperature, exposure and target airflow. Evaluate the chosen configuration in the complete assembly.
What determines airflow?+
Membrane structure, exposed area and pressure differential all affect flow. Compare data only when units and test conditions are aligned.
Does an IP rating apply to my finished product?+
A component result does not establish the rating of the complete enclosure. Seals, mounting and other openings must be tested as part of the final assembly.
Can a vent eliminate condensation?+
Venting can support pressure and moisture exchange. Condensation also depends on temperature, humidity, enclosure geometry and operating conditions.
Related configurations

0.8 mm PE high-barrier foil vent liner
View configuration →
Grooved foam vent liner
View configuration →